Quality System
Quality System & Standards
The standards, traceability and management arrangements that govern the work described on this site.
Overview
Pittsburgh CMM Calibration and Repair places calibration and verification work with laboratories accredited to ISO/IEC 17025. Accreditation and the certificate issued under it belong to the laboratory performing the measurement. Each request is scoped against that laboratory's published scope of accreditation before a quotation is issued, and accredited items are identified separately from non-accredited items on both the quote and the certificate.

Standards Referenced
Work described on this site is performed under ISO/IEC 17025:2017.
Accreditation, where it is referenced anywhere on this site, is the accreditation held by the laboratory that performs the work, and it extends only to the measurements listed in that laboratory's published scope. Measurements outside a published scope are performed and reported as non-accredited work and are identified as such on the certificate. No accreditation is claimed here that is not held by the party performing the measurement.
What a quotation is accompanied by is described on the accreditation documentation page.

Metrological Traceability
Measurements are traceable to the SI through NIST, documented as an unbroken chain of comparisons, each carrying a stated uncertainty. Certificates state the reference standards used, the method, environmental conditions where they affect the result, and the reported measurement uncertainty with its coverage factor. Where a statement of conformity is given, the decision rule applied is stated on the certificate, consistent with ISO 14253-1 and the documentation requirement in ISO/IEC 17025:2017. Where adjustment or repair occurs, results are reported before and after.
Traceability is captured at the level of the measurement. The certificate records which reference was used, how that reference stood in its own calibration interval, and the chain that links it to the SI unit. Where a reference is subsequently found out of tolerance, work measured against it since its previous calibration is reviewed and affected parties are notified.
Equipment and Maintenance
Work covers bridge, gantry and cantilever coordinate measuring machines, portable articulated arms, granite surface plates, gauge blocks, and ring and plug gauges. Documented procedures govern request review, method selection, result review and release, and a complaints-and-appeals process available to any customer disputing a result. Out-of-tolerance findings are reported with as-found data intact, so a customer can run its own impact assessment back to the last passing calibration before any adjustment is accepted.
Reference equipment is individually identified and kept under controlled conditions, with a defined recalibration interval that is shortened where drift data supports it. Items that have been damaged or overloaded, or that give results which do not stand up, are withdrawn and labelled, and are not used again until checked and released in writing.
Management System
The work sits inside a documented management system:
- 01
Controlled documents
Procedures carry issue and revision status.
- 02
Retained records
Retained for a defined period and retrievable against a certificate number.
- 03
Audit and review
Internal audit and management review run on a schedule.
- 04
Corrective action
Nonconforming work and improvement actions are tracked to closure, and their effectiveness is checked afterwards.
Impartiality and Complaints
Impartiality risks are assessed and controlled, and findings are reported as measured even where the commercial result is unwelcome. Complaints and appeals are treated as a formal input rather than an inconvenience — the process, including the response commitment, is set out on the complaints policy page. How results should and should not be read is covered on the disclaimer page.

Need records for a vendor-approval file?
Scope, method statements and traceability detail are supplied with the quotation.